Safer dental procedures with new biosafety air curtain device

Safer dental procedures with new biosafety air curtain device

Researchers at the National Dental Research Institute Singapore (NDRIS) have developed a novel device that aims to limit the spread of aerosols generated during dental procedures, thereby lowering the risk of COVID-19 crosscontamination in the dental setting. Known as Aeroshield, the innovation utilizes air curtain technology to create an air barrier, segregating aerosols generated at the patient’s mouth from the dentist.

Developed for the safety of dental practitioners

The Aeroshield was developed with the safety of dental practitioners in mind. Working within close proximity to patients’ mouths and carrying out many aerosol-generating procedures, dentists and their assistants are usually at very high risk of infection from the SARS-CoV-2 virus—which causes COVID-19—via cross-contamination.

Contaminated aerosols can travel one meter horizontally and half a meter vertically. According to a 2020 survey conducted among 669 dentists from 30 countries, 87 percent of respondents were afraid of getting infected by the SARS-CoV-2 virus from dental procedures, 66 percent wanted to close dental practices, and 92 percent feared carrying the infection back to their families.

“During the Circuit Breaker period in Singapore in 2020, patient attendances fell by 35 to 60 percent, as dentists could only see to emergency cases. Even with the gradual resumption of dental services after the Circuit Breaker, many patients delayed their dental visits for fear of COVID-19 risks,” shared Clinical Associate Professor Goh Bee Tin, Principal Investigator of the Aeroshield project and Director, NDRIS. “As the Aeroshield significantly cuts down the amount of aerosol contamination, even for other diseases which spread via droplets, patients can access dental care with more assurance, and dentists have better chances of financial sustainability,” she said.

Benefits of using Aeroshield

Repurposing the idea of an air curtain, the Aeroshield is practical and easy to set up and operate. It adopts a plug-and-play system so that dentists can simply attach it to the dental chair and air compressor outlet. It boasts a sleek and functional design, without the need for any modifications to existing dental room equipment, and does not require any moving internal components nor consumables.

Air curtains are directed as air jets used as a barrier to prevent contamination between adjacent environments without using a physical structure. This ensures no disruption to the existing clinical workflow and users will not experience any discomfort despite working with the additional barrier. The aerosols generated are then redirected by the air curtain and removed by a high volume evacuator, which is currently already used in routine dental practice. A simple wipe-down is adequate to disinfect the dental room, as per existing infection prevention and control practices.

Apart from dentistry, the Aeroshield also has potential to be adapted for use by other medical practitioners who are at high risk of aerosol exposure, such as those in ophthalmology, otolaryngology and anaesthesiology.

Efficacy of the Aeroshield

In an efficacy evaluation test, it was found that the most contaminated areas of dental practitioners tend to be at the chest and lower right arm, and even the inner surface of the dental assistant’s face shield. With the Aeroshield in place, results showed that contamination in these same regions was reduced by up to five times. In particular, using the Aeroshield reduced contamination on the top inner surface of the dentist’s face shield by about three times, and up to five times on the top and bottom inner and outer surfaces of the dental assistant’s face shield.

Source: Read Full Article